General Equipment
>
Gel documentation system |
|
|
| |
 |
|
Major Science Compact 0.4 MP CCD Image System
Cat No:
UVCI-01-254 (with 254nm UV Transilluminator)
UVCI-01-312 (with 312nm UV Transilluminator)
UVCI-01-365 (with 365nm UV Transilluminator)
Descriptions:
| • |
0.4 megapixels CCD camera and built-in UV Transilluminator. |
| • |
Fluorescent imaging. |
| • |
10.4" Colour touch screen technology and built-in computer for fast and easy imaging. |
| • |
Mounted USB port for saving images and transferring images. |
| • |
Compact configuration and size. |
| • |
Inner 2 x 3 watt white light LED for uniform white light illumination. |
| • |
Safety door switch. |
| • |
Connect port for thermal printer. |
| • |
EtBr and SYBR green filter are available. |
| • |
Convenient access on the left side for gel operation. |
| • |
Universal rated voltage: 100 ~ 240V. |
|
| |
| |
 |
|
Major Science Compact 1.4 MP CCD Image System
Cat No:
UVCI140-254 (with 254nm UV Transilluminator)
UVCI140-312 (with 312nm UV Transilluminator)
UVCI140-365 (with 365nm UV Transilluminator)
UVCI140-254/365 (with 254/365nm UV Transilluminator)
UVCI140-254/312 (with 254/312nm UV Transilluminator)
Descriptions:
| • |
High resolution 1.4 MP CCD camera |
| • |
10.4” Color Touch Screen |
| • |
Image format: TIFF/BMP/JPEG/PNG |
| • |
Selectable 8 or 16 bit file storage |
| • |
Images can be exported through a network Ethernet cable or USB key |
| • |
Modular system allows for easy upgrade of hardware or software |
| • |
Small footprint helps conserve limited lab space |
| • |
Dual side door access for gel cutting |
| • |
Single or dual wavelength modules available |
| • |
2 x 3W LED white light |
| • |
Supports Mitsubishi P95DW USB thermal-printer |
| • |
Safety door switch device |
|
| |
| |
 |
|
Major Science Compact 2.0 MP CCD Image System
Cat No:
UVCI200-254 (with 254nm UV Transilluminator)
UVCI200-312 (with 312nm UV Transilluminator)
UVCI200-365 (with 365nm UV Transilluminator)
UVCI200-254/365 (with 254/365nm UV Transilluminator)
UVCI200-254/312 (with 254/312nm UV Transilluminator)
Descriptions:
| • |
High resolution 2.0 MP CCD camera |
| • |
10.4” Color Touch Screen |
| • |
Image format: TIFF/BMP/JPEG/PNG |
| • |
Selectable 8 or 16 bit file storage |
| • |
Images can be exported through a network Ethernet cable or USB key |
| • |
Modular system allows for easy upgrade of hardware or software |
| • |
Small footprint helps conserve limited lab space |
| • |
Dual side door access for gel cutting |
| • |
Single or dual wavelength modules available upon request |
| • |
2 x 3W LED white light |
| • |
Supports Mitsubishi P95DW USB thermal-printer |
| • |
Safety door switch device |
|
| |
| |
 |
|
Isogen Proxima 10 Phi
Cat No:
IM-520-0500
Descriptions:
| • |
General purpose gel documentation system. |
| • |
Fluorescence ready. |
| • |
12 bit CCD camera (4096 gray levels). |
| • |
Image positioning / Slant correction. |
| • |
Electronic optical zoom (6X). |
| • |
White light top illumination. |
| • |
Digital USB-2 camera 1.3 Mio pixels. |
Applications:
| For basic documentation purposes. It can be used for imaging ethidium bromide stained DNA agarose gels, Coomassie stained gels, SYBR Green stained gels, SYPRO Ruby stained gels, film archiving and petri dishes. |
|
| |
| |
 |
|
Isogen Proxima 16 Phi
Cat No:
IM-520-0600
Descriptions:
| • |
General purpose gel documentation system. |
| • |
More sensitive and allow more accurate quantification than with the ProXima 10 Phi. |
| • |
Fluorescence ready. |
| • |
16 bit CCD camera (65536 gray levels). |
| • |
Image positioning / Slant correction. |
| • |
Electronic optical zoom (6X). |
| • |
White light top illumination. |
| • |
Digital USB-2 camera 1.5 Mio pixels. |
Applications:
| For imaging ethidium bromide stained DNA agarose gels, Coomassie stained gels, SYBR Green stained gels, SYPRO Ruby stained gels, film archiving and petri dishes. |
|
| |
| |
 |
|
Isogen Proxima 16 Phi+
Cat No:
IM-520-0650
Descriptions:
| • |
High dynamic range general purpose gel documentation system. |
| • |
The ProXima 16 Phi+ has a 16 bit CCD camera (65536 gray levels). |
| • |
Electronic optical iris and electronic optical focus. |
| • |
The ProXima 16 Phi+ is equipped for multi-plexed multi-fluorophore applications. |
| • |
Image positioning / Slant correction. |
| • |
Electronic optical zoom (6X). |
| • |
White light top illumination. |
| • |
Digital CCD USB-2 camera 1.5 Mio pixels. |
|
| |
| |
 |
|
Isogen Proxima C16 Phi+
Cat No:
IM-520-0750
Descriptions:
| • |
High sensitivity chemiluminescence imaging system. |
| • |
ProXima C16 Phi+ has the top of the line 16 bit temperature controlled cooled CCD camera (65536 gray levels). |
| • |
Designed with innovative triple Peltier cooling of the image sensor. |
| • |
Electronic optical iris and electronic optical focus. |
| • |
Image positioning / Slant correction. |
| • |
Electronic optical zoom (6X). |
| • |
White light top illumination. |
| • |
Digital CCD USB-2 camera 1.5 Mio pixels. |
|
| |
| |
 |
|
Vilber Bio-link Crosslinker
Cat No:
611120811 (254nm)
611120821 (312nm)
Descriptions:
| The Bio-Link crosslinker is a complete, microprocessor controlled UV irradiation system, mainly dedicated to the linking of nucleic acid to membranes and elimination of PCR contamination. |
| • |
Precise irradiation in either energy (Joules/cm²) or time (seconds) |
| • |
Pre-set programme for dosage of 0.120 J/cm² tooptimised nucleic acid immobilisation |
| • |
9 pre-set programmes for UV energy exposure |
| • |
9 pre-set programmes for time exposure |
| • |
Manual setting of UV energy or time exposure |
| • |
Storage of the last UV setting |
| • |
Tactile membrane keypad |
| • |
Large L.E.D. readout |
| • |
Protective quartz disk on the UV sensor cell |
| • |
Spacious UV exposure chamber in stainless steel |
| • |
Safety interlock door with UV blockingobservation window |
| • |
Automatic restart with no loss of informationif breaking-off of circuit |
| • |
Dual safety fuses |
| • |
UV wavelength inter-changeability |
Applications:
| Crosslinking of DNA and RNA to nylon or nitrocellulose membranes for blots, Nicking of ethidium bromide stained DNA inagarose gels, RecA mutation screening, Elimination of PCR contamination, UV sterilisation, UV curing of polymers, Gene mapping for creating cleavage-inhibitingthymine dimers |
|
| |
| |
 |
|
Vilber UV Face Shield
Cat No:
910010021
The MP-80 is recommended for the protection of the eye and the face
910010031
MP-800 face shield has two lateral protections to cover the operator ears in addition to his eyes and face.
Descriptions:
Lamps are powerful source of UV radiation. UV radiation is dangerous for unprotected eyes and skin. Short (254nm) and medium (312nm) waves are dangerous for the eyes and the skin. Long waves could affect sensitive persons or person under medical treatment.Therefore itis strongly recommendedto protect yourself against UV radiation by wearing face shields.
|
| |
|
|
|