PALL MinimateTM Tangential Flow Filtration System

Cat No:
OAPMP220 (Minimate TFF, System 220V)

Descriptions:
Ready to Use – Plug in a Minimate TFF capsule, add sample and turn on the pump to start processing. The Minimate TFF system includes all the hardware, tubing and fittings needed to get your TFF process up and running quickly
High Concentration Factors – The low system working volume achieved through the use of a conical bottom reservoir and compact design enable high concentration factors from up to 1L or more of sample to be achieved. Concentrate your sample down to as little as 5 mL
Secure – All wetted components are made from low protein-binding, chemically resistant, USP Class VI materials The system has a very low volume and interior fluid contact area. Fluid does not pass through and is not retained in the pump mechanism, as it does with diaphragm or piston pumps. If cross-contamination is a concern, simply change the tubing between samples. The Easy-Load® pump head makes it easy to replace the system tubing.
Gentle Processing – Roller head peristaltic pumps are the choice for critical applications such as fragile biomolecules. Alternative pumps use direct mechanical action on the fluids, and increase the possibility of damage to cells or proteins
Easy Cleaning and Maintenance – System components are designed for easy assembly and disassembly, no tools required. Tubing and fitting replacement is simple and quick. Slip nuts for luer locks eliminate tubing kinks

All fittings are simple and inexpensive to replace. Three-way valves at the reservoir inlet and outlet can be used for sample recovery or spill free addition of rinse and cleaning fluids.
Efficient – Continuous diafiltration for desalting or buffer exchange can be performed unattended. The diafiltration buffer container is connected to the lid of the feed reservoir. By simply pulling a vacuum on the feed reservoir, new buffer is drawn into the feed reservoir at the same rate filtrate is generated. The stir plate ensures adequate mixing of the buffer addition
Compact Design – Saves valuable bench space, making the entire fluid path easily accessible for built-in flexibilit
Process Monitoring – Pressure gauge enables monitoring of feed pressure

Applications:
Concentrate and desalt proteins, peptides or nucleic acids (DNA, RNA, oligonucleotides)
Recover antibodies or recombinant proteins from clarified cell culture media
Process metal sensitive enzymes and molecules
Separate (fractionate) large from small biomolecules
Concentrate viruses or gene therapy vectors
Prepare samples prior to column chromatography
Concentrate samples after gel filtration
Depyrogenate water, buffers, and media solutions

Accessories:
Cat no. Descriptions
OAD65C12 Minimate TFF Capsule with 650 Da Omega membrane
OA001C12 Minimate TFF Capsule with 1 kDa Omega Membrane
OA003C12 Minimate TFF Capsule with 3 kDa Omega Membrane
OA005C12 Minimate TFF Capsule with 50 kDa Omega Membrane
OA010C12 Minimate TFF Capsule with 10 kDa Omega Membrane
OA030C12 Minimate TFF Capsule with 30 kDa Omega Membrane
OA050C12 Minimate TFF Capsule with 50 kDa Omega Membrane
OA070C12 Minimate TFF Capsule with 70 kDa Omega Membrane
OA100C12 Minimate TFF Capsule with 100 kDa Omega Membrane
OA300C12 Minimate TFF Capsule with 300 kDa Omega Membrane
OA500C12 Minimate TFF Capsule with 500 kDa Omega Membrane
OA990C12 Minimate TFF Capsule with 1000 kDa Omega Membrane
OARES220 Minimate Reservoir ASM,220V